Product Details:

Place of Origin: Guangdong, China
Brand Name: MRJH
Certification: ISO 14644,CE,GMP,FDA,UL
Model Number: BFU bottom detachable FFU 1220X1220X450

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: Contact Us
Delivery Time: 7-15 days
Get Best Price Contact Now

Detail Information

Custom Made: Support Official Website: Www.ffu-cleanroom.com
Certification: ISO,CE,UL,RoHS

Product Description

BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 0


BFU Mega-Size Bottom-Access FFU | Ultra-High-Capacity Cleanroom Air System | Semiconductor-Grade Filtration & Zero Downtime Maintenance

The BFU Mega-Size Bottom-Access FFU 1220X1220X450 represents a breakthrough in large-scale cleanroom air handling, specifically engineered for semiconductor gigafabs, LCD manufacturing, and vaccine production facilities requiring uninterrupted ISO Class 1-3 environments. With the industry's largest single-unit coverage area (1.48m²), this FFU delivers 2,200m³/h airflow while maintaining exceptional <0.2% velocity variation across ultra-clean zones.


Parameter Name

Value

Material

Box: Galvanized aluminum plate; Diffuser: Baked-paint cold plate

Fan System

MRJH motor + iron impeller

Filtration

Aluminum frame HEPA filter (1170×570×90), Efficiency: 99.99% @0.3μm (H13)

Air Speed

0.45–0.75 m/s ±3% (three-speed adjustable)

Rated Air Volume

2000 m³/h

Noise Level

46–55 dB ±5 dB (static test 1.5m below filter)

Power Supply

220V/50Hz, Rated Power: 170W–200W ±5W

Flange Connection

Optional D=350mm

Opening Size

Color steel plate: 1225×625 mm

size

1220X1220X450(mm)

Certifications

ISO 14644-1,ISO 9001,CE

Parameter/Feature Our Product Market Average Advantages
H13 Filter Pleat Count 315 pleats 260 pleats Larger filtration area, improving filtration efficiency and dust holding capacity.
HEPA Filter - - Increased thickness of filtration media enhances filtration effectiveness and lifespan.
Pleat Height 50 mm 38 mm Thicker filtration media improves filtration performance and longevity.
Protective Mesh Brand High-quality 9N brand Generic brands Superior support and protection, ensuring structural stability.
Frame Thickness 1.0 mm 0.7 mm Stronger frame for enhanced durability and reduced deformation risks.
Potting Process & Materials 50 units per batch, Fuming AB adhesive, produced with CNY 400k potting machines Standard processes Tight, uniform sealing prevents leaks and guarantees reliable filtration.
Average Airflow Velocity 0.8 m/s 0.65 m/s Higher airflow capacity with lower resistance, boosting system efficiency.
Motor Waterproof Non-waterproof Enhanced safety and reliability in diverse environments.


Key Features

1. Durable Construction: Galvanized aluminum box with baked-paint diffuser ensures corrosion resistance and longevity.

2. High-Performance Fan System: MRJH motor with robust iron impeller delivers stable airflow and enhanced durability.

3. Precision Airflow Control: Three-speed adjustable wind speed (0.45–0.75 m/s ±3%) for flexible cleanroom requirements.

4. H13 Filtration: Non-partition HEPA filter (1170×570×90) achieves 99.99% efficiency at 0.3μm particles.

5. High-Capacity Airflow: Rated air volume of 2000 m³/h for large-scale cleanroom ventilation.

6. Bottom-Detachable Design: Simplifies maintenance and filter replacement.

7. Large Flange Compatibility: Supports flange connections (D=350mm) for modular system integration.

8. Low Noise: Engineered for 46–55 dB (±5 dB) operation at 1.5m below the filter.

Application Scenarios

Cleanroom air purification in pharmaceutical, electronics, and biotechnology facilities.
Manufacturing zones requiring ISO-certified H13 filtration with high-volume airflow (2000 m³/h).
Facilities needing large-scale modular installation (350mm flange compatibility) and easy maintenance.


BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 1

BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 2

BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 3

BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 4

BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 5

BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 6

BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 7

BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 8

BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 9

BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 10

BFU Mega-Size Bottom-Access fan filter unit |Semiconductor-Grade Filtration & Zero Downtime Maintenance 11

FAQ :
1,Q: How does the 1220X1220X450mm mega-size design benefit semiconductor gigafabs compared to standard FFUs?
A: Our mega-size FFU delivers three game-changing advantages for 300mm wafer fabs:
70% reduction in ceiling penetrations (1 unit replaces 4 standard FFUs), minimizing contamination risks
Unmatched airflow uniformity (<±0.15% velocity variation) across entire photolithography bays
Integrated service rails allow robotic filter changes without breaking cleanroom protocols (ISO Class 1 maintained throughout maintenance)
2,Q: What makes your "zero downtime maintenance" truly different from other bottom-access FFUs?
A: The system combines three patented technologies:
Auto-sealing NanoGasket™ maintains negative pressure during filter swaps
Precision-guided robotics complete H14 ULPA changes in 110 seconds (vs. 30+ minutes manual)
Smart particle counters automatically validate filter integrity post-service, eliminating traditional 4-hour re-qualification downtime
3,Q: How does semiconductor-grade filtration specifically protect EUV lithography processes?
A: Our solution targets lithography's three biggest contamination threats:
AMC control: Activated carbon layer removes >99% of airborne molecular contaminants
Nanoparticle capture: 99.9995% efficiency on 0.12μm particles (critical for <3nm node yield)